Geophysical and geotechnical assessment of Obiaruku-Agbor road failure in Western Niger-Delta, Nigeria
Keywords:
Geophysical technique, Engineering assessment, Subsoil, Strength characteristics, Road constructionAbstract
A geophysical and geotechnical survey was carried out along the Obiaruku-Agbor Expressway in Delta State, Nigeria to determine the causes of its deterioration. The study used a 2D electrical resistivity approach using the ABEM SAS 1000 Terrameter and yielded subsurface resistivity values ranging from 5.12 Ohm-m to 4418 Ohm-m. The geo-electric resistivity result showed that the base, sub-base, infill and embarkment soil types range from an interchange of clay,sandyclay, clay sand, fine sand and coarse sand.The high percentage of low-resistivity soil indicated that the building materials were not appropriate. Using soil samples, gathered for various geotechnical parameter tests for surface sub-base and base materials in accordance with British standards, the geotechnical characteristics of the research sites were ascertained. The findings show that A-2 and A-7 soil types are the most common types. The soils from the stable sections have a higher specific gravity (2.59-2.89) and a smaller amount of clay (16.9 %) than the soils from the failed portions of A-7-6 which suggests substandard sub-grade materials. These soils correspond to A-2-6 on the AASHTO classification system. The bulk of soils from failed sections had significant values of linear shrinkage (> 8%), a large proportion of fine particles (> 40%), and pore water pressure occurred as a result in a loss of soil index strength. The majority of fines particles in lateritic soils, low California bearing ratio (08–63% un-soaked), intermediate and high OMC above guideline for most soil samples (07.4–20.1), maximum dry density (MDD) (<2000 kg/m3), and liquid limit (20.9–58.7) are the main causes of the observed degree of instability. Poor geotechnical characteristics in the lateritic and sub-grade soils of failed sections imply that they should not be used as sub-grade materials in other engineering works, let alone in the building of new roads. It is stressed that lateritic soils are crucial for precise sub-grade soil assessment in detail sampling for highways. When these values were compared to the standard, it became clear that the main reasons for road collapse were thin pavement, inadequate drainage, water-logged sands, low-quality infill, incompetent clayey materials beneath the built road, and neglect. It is consequently advised that a well-designed, organized drainage system be built and that the soils be stabilized or replaced with materials that adhere to standards.The results of this inquiry will be useful in the repair and rehabilitation of the road's deteriorating sections and it is recommended that a thorough record of this study be kept for future reference.
Published
How to Cite
Issue
Section
Copyright (c) 2024 Ogheneovo Akpoyibo, Ezekiel Onoriode Abriku, F. C. Ugbe, Ochuko Anomohanran

This work is licensed under a Creative Commons Attribution 4.0 International License.
How to Cite
Similar Articles
- A. A. Faremi, S. S. Oluyamo, K. D. Adedayo, Y. A. Odusote, O. I. Olusola, Influence of Silicon Nanoparticle on the Electrical Properties of Heterostructured CdTe/CdS thin films based Photovoltaic Device , Journal of the Nigerian Society of Physical Sciences: Volume 3, Issue 3, August 2021
- Idongesit E. Eteng, Udeze L. Chinedu, Ayei E. Ibor, A stacked ensemble approach with resampling techniques for highly effective fraud detection in imbalanced datasets , Journal of the Nigerian Society of Physical Sciences: Volume 7, Issue 1, February 2025
- J. O. Coker, A. A. Rafiu, N. N. Abdulsalam, A. S. Ogungbe, A. A. Olajide, A. J. Agbelemoge, Investigation of Groundwater Contamination from Akanran Open Waste Dumpsite, Ibadan, South-Western Nigeria, using Geoelectrical and Geochemical Techniques , Journal of the Nigerian Society of Physical Sciences: Volume 3, Issue 2, May 2021
- Nikita Bhardwaj, Monika Saini, Ashish Kumar, Estimation of reliability characteristics of single-unit repairable system with preventive maintenance and server arrival time , Journal of the Nigerian Society of Physical Sciences: Volume 8, Issue 2, May 2026
- Alaba Joseph Adebayo, Ilemobayo Ifedayo Oguntimehin, Studies on the effects of kaolin filler concentrations on the thermal and mechanical performance of furan–lignin foam formulations , Journal of the Nigerian Society of Physical Sciences: Volume 8, Issue 3, August 2026
- A. Olajide, S. Bayode, T. Fagbemigun, A. Oyebamiji, J. Amosun, A. Owasanoye, Evaluation of Aquifer Protective Capacity and Groundwater Potential in Part of Iju, Akure-North, Ondo State, Nigeria , Journal of the Nigerian Society of Physical Sciences: Volume 2, Issue 3, August 2020
- M. Kida, S. Adamu, O. O Aduroja, P. T Pantuvo, Numerical Solution of Stiff and Oscillatory Problems using Third Derivative Trigonometrically Fitted Block Method , Journal of the Nigerian Society of Physical Sciences: Volume 4, Issue 1, February 2022
- Lek Ming Lim, Yang Lu, Ahmad Sufril Azlan Mohamed, Majid Khan Majahar Ali, Data safety prediction using YOLOv7+G3HN for traffic roads , Journal of the Nigerian Society of Physical Sciences: Volume 6, Issue 3, August 2024
- Bolarinwa Bolaji, Abdullahi Ibrahim, Favour Ani, Benjamin Omede, Godwin Acheneje, A model for the control of transmission dynamics of human monkeypox disease in Sub-Saharan Africa , Journal of the Nigerian Society of Physical Sciences: Volume 6, Issue 2, May 2024
- Chinedu L. Udeze, Idongesit E. Eteng, Ayei E. Ibor, Application of Machine Learning and Resampling Techniques to Credit Card Fraud Detection , Journal of the Nigerian Society of Physical Sciences: Volume 4, Issue 3, August 2022
You may also start an advanced similarity search for this article.