A comparison of the performance and energy resolution of CdTe and Si detectors in the X-ray Fluorescence studies of metal samples and Alloys
Keywords:
X-ray fluorescence, Cadmium Telluride detector, Silicon detector, Energy resolution, energy efficiencyAbstract
X-ray fluorescence provides a powerful means of non-destructively determining the elemental composition of a sample. X-rays from a Molybdenum (Mo) source was fired on copper, molybdenum, lead, steel and brass samples to determine their composition and relative abundance of their constituent elements. Two different detectors: the Cadmium Telluride (CdTe) and Silicon(Si) detectors were used to pick up the signals from the scattering of the X-rays at the sample surfaces and their energy resolutions as well as efficiencies were compared. With a non-noisy amplifier, the Si detector had a higher resolution (0.27 % ) when compared to the 0.38 % for the CdTe detector but it had a lower efficiency when compared to that of the CdTe detector. It was also discovered that higher energies produced lower detector efficiencies.
Published
How to Cite
Issue
Section
Copyright (c) 2022 Iniobong P. Etim, Rebecca Emmanuel Mfon

This work is licensed under a Creative Commons Attribution 4.0 International License.
How to Cite
Similar Articles
- Ammar A. Oglat, Abdallah Al Said, Naser M. Ahmed, Mohammed Dawood Salman, Zinc oxide nanoparticles and nanorods: advanced sunscreen ingredients for enhanced UV protection and radiation filtration , Journal of the Nigerian Society of Physical Sciences: Volume 7, Issue 4, November 2025
- Samy A. Khalil, Performance Evaluation and Statistical Analysis of Solar Energy Modeling: A Review and Case Study , Journal of the Nigerian Society of Physical Sciences: Volume 4, Issue 4, November 2022
- Ibukun Akinsola, Aderemi Babatunde Alabi, Muibat A Soliu, Taiye Akomolafe, Optimization of Method and Components of Enzymatic Fuel Cells , Journal of the Nigerian Society of Physical Sciences: Volume 1, Issue 4, November 2019
- C. A. Onate, I. B. Okon, E. S. Eyube, E. Omugbe, A. D. Ahmed, Computation of vibrational partition function: a comparative analysis between Poisson summation and classical limit , Journal of the Nigerian Society of Physical Sciences: Volume 8, Issue 1, February 2026
- Emmanuel Agboeze, Henry Okechukwu Agboeze, Theresa Orieji Uchechukwu, Anayo Vitus Ofordile, Chukwuebuka Gabriel Eze, Environmental and health risk assessment of cadmium, zinc,iron, copper in crops and soil at Enugu State dumpsite , Journal of the Nigerian Society of Physical Sciences: Volume 8, Issue 1, February 2026
- Benson Ade Eniola Afere, On the fourth-order hybrid beta polynomial kernels in kernel density estimation , Journal of the Nigerian Society of Physical Sciences: Volume 6, Issue 1, February 2024
- Dyavappa B M, The Mass Resolution of Ca, K Isotopes and CO, N2 and C2H4 Isobars in Isotopes Separator On-Line trap Mass spectrometry
- A. Shamsudeen, Shuaibu S., S.G. Abdu, M. S. Abubakar, Abdullahi lawal, First-principles calculations of Fluorine-doped Titanium dioxide: A prospective material for solar cells application , Journal of the Nigerian Society of Physical Sciences: Volume 1, Issue 4, November 2019
- Arezu Jahanshir, Jalil Naji, Relativistic correction on bottomia within the gaussian basis function method , Journal of the Nigerian Society of Physical Sciences: Volume 7, Issue 4, November 2025
- Sylvester J. Gemanam, Nursakinah Suardi, Barnabas A. Ikyo, Samson Damilola Oluwafemi, Terver Daniel, Samuel T. Kungur, Biostimulation Effects and Temperature Variation in Stimulated Dielectric Substance (Diabetic Blood Comparable to Non-Diabetic Blood) Based on the Specific Absorption Rate (SAR) in Laser Therapy
You may also start an advanced similarity search for this article.

